PolyPerf Safe

POLYPERF ® Safe and PPS Quick


POLYPERF ® Safe

THE SAFETY HUBER NEEDLE WITH SINGLE HAND ACTIVATION

Positive pressure

• According to implantable port using recommendations (1).
• Withdrawal of the needle with only one hand.


Prevention of needlestick injury

• Eliminates the risk of needlestick injury.
• No rebound effect at the withdrawal of the needle.
• No risk of contact with the body of the needle (2).
• Total protection up to discarding in sharps container.

 

 

PPS Quick ®

PROTECTION FOR NURSE AND PATIENT: WITH PRESEALED, CLOSED NEEDLE-FREE LUER ACCESS DEVICE (BD Q-SYTE )

Nurse

• Further prevention of needlestick injury
• Simplified handling.


Patient

• Prevention of catheter-related bloodstream infection (CRBI):
CLOSED LUER ACCESS DEVICE pre-sealed BD Q-SYTE™
- Curved split-septum easy to disinfect
- Clear body (flushing control)
- Adequate for high flow
- Reduced air embolism risk (automatic closure after luer tip removal)
• Prevention of catheter obstruction: positive pressure during needle removal

 

GaugeØ
of the needle
(mm)
Length of
the needle
(mm)
References without lateral
injection site
References with lateral
injection site
References with BD Q-Syte™
on the main line (without Y-site)
References with BD Q-Syte™
on the Y-connector
       22G 0,7 15 601507* 611507* 621507* 631507*
22G 0,7 17 601707 611707 621707 631707
22G 0,7 20 602007 612007 622007 632007
22G 0,7 25 602507 612507 622507 632507
22G 0,7 30 603007 613007 623007 633007
22G 0,7 35 603507 613507 623507  633507
       20G 0,9 15 601509* 611509* 621509* 631509*
20G 0,9 17 601709 611709 621709 631709
20G 0,9 20 602009 612009 622009 632009
20G 0,9 25 602509 612509 622509 632509
20G 0,9 30 603009 613009 623009 633009
20G 0,9 35 603509 613509 623509 633509
       19G 1,1 15 601511* 611511* 621511* 631511*
19G 1,1 17 601711 611711 621711  631711
19G 1,1 20 602011 612011 622011  632011
19G 1,1 25 602511 612511 622511  632511
19G 1,1 30 603011 613011 623011 633011
19G 1,1 35 603511 613511 623511 633511

Rerferences in bold are only available upon request with a minimum lead time of 12 weeks.
* For pediatric use only.

(1) According to implantable port using recommandations, HAS guideline, Decembre 2000.
(2) Biomatech study n°148381 - 28 june 2012 - p.64-66.

POLYPERF® Safe and PPS® Quick Huber Needle are packaged in cartons of 12 units. Sterilized using ethylene oxide.
PHTALATES FREE - LATEX FREE
POLYPERF® Safe and PPS® Quick are registered trademarks of PEROUSE MEDICAL

(1) According to implantable port using recommandations, HAS guideline, Decembre 2000.
(2) Biomatech study n°148381 - 28 june 2012 - p.64-66.
POLYPERF® Safe and PPS® Quick Huber Needle are packaged in cartons of 12 units. Sterilized using ethylene oxide.
PHTALATES FREE - LATEX FREE
POLYPERF® Safe and PPS® Quick are registered trademarks of PEROUSE MEDICAL.
Positive pressure
Normal position for use
(horizontal piston)
before withdrawal.
Preparation: lift the piston from the horizontal
position to the vertical position.
Using your thumb, lower the piston to put it in contact
with the skin and simultaneously lift the extractor (with
an upwards movement) until there is a CLIC corresponding
to the total locking of the needle. This final operation
eliminates any risk of accidental needlestick injury.
WITHDRAWAL OF THE NEEDLE
PROTECTION FOR NURSE AND PATIENT: WITH PRESEALED, CLOSED NEEDLE-FREE
LUER ACCESS DEVICE (BD Q-SYTE )
PROTECTION
FROM
NEEDLESTICK INJURIES
POLYPERF Safe and PPS Quick
Safety huber needles
PROMECON

CONTACT PROMECON GMBH

Kreuslerstraße 10 | 20095 Hamburg

Tel. : +49 40 3690 1690
Fax : +49 40 3690 1699